Multi meter Portavo 904 X Multi

The world’s only portable device for liquid analysis with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points. It is compatible with almost all analog and Memosens process sensors. Memosens sensors with different parameters can be checked without changing the sensor cable.

  • The new MemoLog function allows the user to log calibration data from various Memosens measuring points, which can then be easily transferred to a computer via the standard USB connection. The Paraly SW 112 software enables user-friendly management of all recorded data
  • A sensor quiver protects the sensor from damage and drying out
  • The high-performance polymer housing ensures low water absorption and high impact resistance
  • Over 1000 hours of measurement with a single set of batteries (4 x AA)
  • Data logger with 5000 values
  • The mineral glass display is perfectly readable even after years
  • The world’s only portable device for liquid analysis in hazardous locations
  • Specifications
  • pH/mV input (analogue):
    pH:
    mV:

    -2 to 16 (<0.01)
    -1300 to 1300 (<1% meas. val.,<0.3mV/K)
  • Temperature input:
    Temperature with NTC 30 kO:
    Temperature with Pt 1000:

    -20 to +120°C (<0.2K)
    -40 to +250°C (<0.2K)
  • Memosens input (ISFET):
    pH:
    mV:
    Temperature range:

    -2.000 to +16.000 (<0.01)
    -2000 to +2000 (<1% meas. val.,<0.3mV/K)
    -50 to +250°C (<0,2K)
  • Memosens input, Redox:
    mV:
    Temperature range:

    -2000 to +2000 (<1% meas. val.,<0.3mV/K)
    -50 to +250 °C (<0.2K)
  • Conductivity measuring range: 0.001µS/cm (c<0.05cm-1)
    0.01µS/cm (c=0.05 to 0.2cm-1)
    0.1µS/cm (c>0.2cm-1)
  • TDS:
    Salinity:
    Resistivity:
    Concentration:
    0 to 1999mg/l
    0.0 to 45.0g/kg
    00.00 to 99.99MO x cm
    0.00 to 9.99 (w/w) %
  • Conductivity input, Memosens:
    Measuring range Sensor SE 215 MS:

    10µS/cm to 20mS/cm
  • Conductivity input:
    Temperature compensation:
    nLF:

    Linear 0 to 20%/K, ref. temp. adjustable
    0 to 120 °C
  • Memosens input, oxygen (optical):
    Saturation:
    Concentration:

    0.000 to 1000.0%
    000µg/l to 100.00mg/l
  • Partial pressure:
    Temperature measuring range:
    0.0 to 2000mbar
    -20 to+150°C
  • Power supply:
    IP code acc. to DIN EN 60529:
    4 x AA
    IP66/67 with pressure compensation