Multi meters Portavo 907 Multi
The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.
The following logging types can be selected:
- Manual logging
- Time-controlled logging at a fixed interval
- Signal-controlled logging of measured value and temperature
- Combined time and signal-controlled logging
- Threshold-controlled logging with pre-trigger
The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.
User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.
- High-resolution color graphic display
- Transflective and sunlight readable
- Li-ion battery
- Micro USB port and Paraly SW 112 software
- A sensor quiver protects the sensor from damage and drying out
- The high-performance polymer housing ensures low water absorption and high impact resistance
- Intelligent data logger with 10,000 entries and graphical representation
- Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)
- The mineral glass display is perfectly readable even after years
- Specifications
-
pH/mV input (analogue):
pH:
mV:
-2 to 16 (<0.01)
-1300 to 1300 (<1% meas. val.,<0.3mV/K) -
Temperature input:
Temperature with NTC 30 kO:
Temperature with Pt 1000:
-20 to +120°C (<0.2K)
-40 to +250°C (<0.2K) -
Memosens input (ISFET):
pH:
mV:
Temperature range:
-2.000 to +16.000 (<0.01)
-2000 to +2000 (<1% meas. val.,<0.3mV/K)
-50 to +250°C (<0,2K) -
Memosens input, Redox:
mV:
Temperature range:
-2000 to +2000 (<1% meas. val.,<0.3mV/K)
-50 to +250 °C (<0.2K) -
Conductivity measuring range: 0.001µS/cm (c<0.05cm-1)
0.01µS/cm (c=0.05 to 0.2cm-1)
0.1µS/cm (c>0.2cm-1) -
TDS:
Salinity:
Resistivity:
Concentration: 0 to 1999mg/l
0.0 to 45.0g/kg
00.00 to 99.99MO x cm
0.00 to 9.99 (w/w) % -
Conductivity input (analogue):
Measuring range with -
Sensor SE 202:
Sensor SE 204:
2-electrode sensors:
4-electrode sensors: 0.01 to 200µS/cm
1µS/cm to 500mS/cm
0.1µS x c to 200mS x c
0.1µS x c to 1000mS x c -
Temperature input:
Measuring range with NTC 30 kO:
Measuring range with Pt 1000:
-20 to +120°C
-40 to +250°C -
Conductivity input, Memosens:
Measuring range Sensor SE 215 MS:
10µS/cm to 20mS/cm -
Conductivity input:
Temperature compensation:
nLF:
Linear 0 to 20%/K, ref. temp. adjustable
0 to 120 °C -
Memosens input, oxygen (optical):
Saturation:
Concentration:
0.000 to 1000.0%
000µg/l to 100.00mg/l -
Partial pressure:
Temperature measuring range: 0.0 to 2000mbar
-20 to+150°C -
Power supply:
IP code acc. to DIN EN 60529: 4 x AA
IP66/67 with pressure compensation
Toote variatsioonid
Type | Description | Catalog number | PK | Kogus | |
---|---|---|---|---|---|
907 Multi pH | one additional input for analogue pH mesurements | 9.774 720 | 1.00 | ||
907 Multi Oxy | one additional input for analogue/optical oxygen mesurements | 9.774 718 | 1.00 | ||