Multi meters Portavo 907 Multi

The only portable device for all Memosens parameters. Also for conventional analog sensors. The powerful Li-ion battery can be charged in the device via USB. The clear network diagram provides an at-a-glance view of the sensor condition.
The following logging types can be selected:

  • Manual logging
  • Time-controlled logging at a fixed interval
  • Signal-controlled logging of measured value and temperature
  • Combined time and signal-controlled logging
  • Threshold-controlled logging with pre-trigger

The data logger for up to 10,000 entries records point of measurement, annotation, sensor ID, sensor serial number (Memosens), primary value, temperature, time stamp, and device status.

User-friendly software
Portavo 907 proves that a high level of functionality and easy use are not mutually exclusive. It proceeds step by step through the calibration procedure. Technical terms are clearly explained in the context-sensitive help.

  • High-resolution color graphic display
  • Transflective and sunlight readable
  • Li-ion battery
  • Micro USB port and Paraly SW 112 software
  • A sensor quiver protects the sensor from damage and drying out
  • The high-performance polymer housing ensures low water absorption and high impact resistance
  • Intelligent data logger with 10,000 entries and graphical representation
  • Memosens sensors and analog pH sensors can be used on one device (e.g. flat-membrane sensors)
  • The mineral glass display is perfectly readable even after years
  • Specifications
  • pH/mV input (analogue):
    pH:
    mV:

    -2 to 16 (<0.01)
    -1300 to 1300 (<1% meas. val.,<0.3mV/K)
  • Temperature input:
    Temperature with NTC 30 kO:
    Temperature with Pt 1000:

    -20 to +120°C (<0.2K)
    -40 to +250°C (<0.2K)
  • Memosens input (ISFET):
    pH:
    mV:
    Temperature range:

    -2.000 to +16.000 (<0.01)
    -2000 to +2000 (<1% meas. val.,<0.3mV/K)
    -50 to +250°C (<0,2K)
  • Memosens input, Redox:
    mV:
    Temperature range:

    -2000 to +2000 (<1% meas. val.,<0.3mV/K)
    -50 to +250 °C (<0.2K)
  • Conductivity measuring range: 0.001µS/cm (c<0.05cm-1)
    0.01µS/cm (c=0.05 to 0.2cm-1)
    0.1µS/cm (c>0.2cm-1)
  • TDS:
    Salinity:
    Resistivity:
    Concentration:
    0 to 1999mg/l
    0.0 to 45.0g/kg
    00.00 to 99.99MO x cm
    0.00 to 9.99 (w/w) %
  • Conductivity input (analogue):
    Measuring range with
  • Sensor SE 202:
    Sensor SE 204:
    2-electrode sensors:
    4-electrode sensors:
    0.01 to 200µS/cm
    1µS/cm to 500mS/cm
    0.1µS x c to 200mS x c
    0.1µS x c to 1000mS x c
  • Temperature input:
    Measuring range with NTC 30 kO:
    Measuring range with Pt 1000:

    -20 to +120°C
    -40 to +250°C
  • Conductivity input, Memosens:
    Measuring range Sensor SE 215 MS:

    10µS/cm to 20mS/cm
  • Conductivity input:
    Temperature compensation:
    nLF:

    Linear 0 to 20%/K, ref. temp. adjustable
    0 to 120 °C
  • Memosens input, oxygen (optical):
    Saturation:
    Concentration:

    0.000 to 1000.0%
    000µg/l to 100.00mg/l
  • Partial pressure:
    Temperature measuring range:
    0.0 to 2000mbar
    -20 to+150°C
  • Power supply:
    IP code acc. to DIN EN 60529:
    4 x AA
    IP66/67 with pressure compensation

Toote variatsioonid

TypeDescriptionCatalog numberPKKogus 
907 Multi pHone additional input for analogue pH mesurements9.774 7201.00
907 Multi Oxyone additional input for analogue/optical oxygen mesurements9.774 7181.00
907 Multi Condone additional input for analogue conductivity mesurements9.774 7171.00