Photometers MD 100
The Lovibond® MD 100 Photometers are designed for analysis of different parameters in drinking water, industrial process water and waste water. With a total of more than 30 different types, instruments are available for routine testing as well as for special applications. The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. Provided with calibration and software-based adjustment options the MD 100 is suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a shelf life of 5 or 10 years, VARIO powder reagents or using liquid reagents.
- Optics: High-quality Interference Filters
- Wavelength accuracy: ±1 nm.
- Power supply: 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests.
- Automatic switch-off.
- LCD Display (backlit on keypress).
- Internal ring memory for 16 data sets.
- Dimensions (L x W x H): 155 x 75 x 35 mm.
Scope of supply: Photometer in a plastic carrying case, with reagents for 100 tests, cells, batteries and standard accessories.
Optional: IRiM – infrared interface module for data transfer to computer or printer.
Toote variatsioonid
Description | Measuring range | Catalog number | PK | Kogus | |
---|---|---|---|---|---|
Chlorine liquid reagents | 0.02 - 4.0mg/l | 6.252 939 | 1.00 | ||
Chlorine tablet reagents | 0.01 - 6.0mg/l | 7.627 340 | 1.00 | ||
Chlorine powder reagents | 0.02 - 2.0mg/l** / 0.1 - 8.0mg/l*** | 6.251 486 | 1.00 | ||
Copper tablet reagents | 0.05 - 5.0mg/l | 9.699 283 | 1.00 | ||
Chlorine dioxide tablet reagents | 0.02 - 11mg/l | 9.699 281 | 1.00 | ||
Manganese LR tablet reagents | 0.2 - 4.0mg/l | 9.699 284 | 1.00 | ||
3 in 1 Chlorine LR / Chlorine HR / Chlorine dioxide tablet reagents | 0.01 - 6.0mg/l / 5 - 200mg/l / 0.05 - 11mg/l | 9.699 288 | 1.00 | ||
Silicon dioxide tablet reagents | 0.05 - 4.0mg/l | 9.699 286 | 1.00 | ||
Phosphate tablet reagents | 0.05 - 4.0mg/l | 9.699 285 | 1.00 | ||
Iron tablet reagents | 0.02 - 1.0mg/l | 9.699 282 | 1.00 | ||
Ammonium tablet reagents | 0.02 - 1.0mg/l | 9.699 280 | 1.00 | ||
2 in 1 Chloride/pH with liquid reagents | 0.02-4 mg/l Cl2 / 6.5-8.4 pH | 7.910 364 | 1.00 | ||
2 in 1 Chlorine /pH tablet reagents | 0.01 - 6.0mg/l* / 6.5 - 8.4pH | 9.699 287 | 1.00 | ||
5 in 1 Chlorine / pH / Cyanuric acid /Alkalinity-M / Calcium hardness tablet reagents | 0.01 - 6.0mg/l* / 6.5 - 8.4pH / 0 - 160mg/l Cys /5 - 200 mg/l CaCO3(TA); 0 - 500 mg/l CaCO3 (CaH) | 9.699 289 | 1.00 |