Portable gas detectors series 04
Portable gas monitors to detect gases in the surrounding atmosphere. They measure concentrations of toxic gases and oxygen in the atmosphere and issue an alarm when gas concentrations reach preset levels. The alarms are indicated by flashing lamp, intermittent audible buzzer, flashing gas concentration readout and vibration.
- LCD display
- R-sensor and CO-sensor with H2-reduction
- Robust construction
- Water- and dust-proof
- Battery or rechargeable battery operation
- Specifications
- Gas alarm: STEL Alarm, TWA Alarm, Over
- Alarm volume: 80 db
- Humidity: 0 … 95 % RH (OX-04G: 10 … 90 % RH)
- Detection principle: Electrochemical type (OX-04G: galvanic cell type)
- Dimensions (W x D x H): 54 x 24 x 67 mm
- Weight: 93 g
- Power supply: 2 x AAA alkaline batteries, or 2 x AAA rechargeble batteries (Ni-MH)
- Protection class: IP 66/67
- Warranty (sensor): 3 years (OX-04G: 1 year)
Toote variatsioonid
Type | Description | For | Resolution | Measuring range | Temp. range °C | Catalog number | PK | Kogus | |
---|---|---|---|---|---|---|---|---|---|
OX-04G | Ni-MH batteries, operation time approx. 6000 h | Oxygen | 0.1 % | 0 ... 25 % | -20 ... 50 | 6.317 140 | 1.00 | ||
CO-04 | Ni-MH batteries, operation time approx. 6000 h | Carbon monoxide | 10 ppm | 0 ... 500 ppm | -40 ... 60 | 6.317 142 | 1.00 | ||
CX-04 | Alkaline batteries, operation time approx. 4600 h | Carbon monoxide + Oxygen | CO: 10 ppm/ O2: 0.1 % | CO: 0 ... 500 ppm/ O2: 0 ... 25 % | -40 ... 60 | 6.317 147 | 1.00 | ||
CO-04 (C-) | Alkaline batteries, operation time approx. 6200 h | Carbon monoxide -H2 | 10 ppm | 0 ... 500 ppm | -40 ... 60 | 6.317 143 | 1.00 | ||
OX-04 | Alkaline batteries, operation time approx. 3000 h | Oxygen | 0.1 % | 0 ... 25 % | -40 ... 60 | 6.317 137 | 1.00 | ||
OX-04G | Alkaline batteries, operation time approx. 9000 h | Oxygen | 0.1 % | 0 ... 25 % | -20 ... 50 | 6.317 139 | 1.00 | ||
SC-04 | Alkaline batteries, operation time approx. 3000 h | Sulfur dioxide | 0.05 ppm | 0 ... 20 ppm | -40 ... 60 | 6.317 149 | 1.00 | ||
CX-04 | Ni-MH batteries, operation time approx. 3000 h | Carbon monoxide + Oxygen | CO: 10 ppm/ O2: 0.1 % | CO: 0 ... 500 ppm/ O2: 0 ... 25 % | -40 ... 60 | 6.317 148 | 1.00 | ||
CO-04 | Alkaline batteries, operation time approx. 9000 h | Carbon monoxide | 10 ppm | 0 ... 500 ppm | -40 ... 60 | 6.317 141 | 1.00 | ||
SC-04 | Ni-MH batteries, operation time approx. 2000 h | Sulfur dioxide | 0.05 ppm | 0 ... 20 ppm | -40 ... 60 | 6.317 150 | 1.00 | ||
HS-04 | Ni-MH batteries, operation time approx. 6000 h | Hydrogen sulfide | 1 ppm | 0 ... 30 ppm | -40 ... 60 | 6.317 146 | 1.00 | ||
OX-04 | Ni-MH batteries, operation time approx. 2000 h | Oxygen | 0.1 % | 0 ... 25 % | -40 ... 60 | 6.317 138 | 1.00 | ||
HS-04 | Alkaline batteries, operation time approx. 9000 h | Hydrogen sulfide | 1 ppm | 0 ... 30 ppm | -40 ... 60 | 6.317 145 | 1.00 | ||
CO-04 (C-) | Ni-MH batteries, operation time approx. 4200 h | Carbon monoxide -H2 | 10 ppm | 0 ... 500 ppm | -40 ... 60 | 6.317 144 | 1.00 |